Label requirements · France

France Medical Device labeling requirements

Everything a label for medical devices sold in France must carry, item by item with the article of law it comes from. Paste your own label below: Drict shows what it found, on which line, and what is missing.

5 mandatory items · 6 only if they apply

Your points to check appear here.

Medical devices — what a France label must show

What the label must showLaw
Manufacturer’s name and registered addressMDR Annex I 23.2(c)
Lot number (LOT) or serial number (SN)MDR Annex I 23.2(g)
UDI carrierMDR Annex I 23.2(h), Art. 27
Use-by date, or the date of manufacture when there is noneMDR Annex I 23.2(i)(j)
The indication that it is a medical device (“MD”)MDR Annex I 23.2(q)

Only when it applies

These items are needed only for some products, claims or packs — read each one against your product.

What the label must showLaw
Authorised representative in the EU (“EC REP”), if the manufacturer is outside the UnionMDR Annex I 23.2(d)
Importer’s name and address, for an imported deviceMDR Art. 13(3)
Sterile state and method of sterilisationMDR Annex I 23.2(l)
Special storage or handling conditionsMDR Annex I 23.2(k)
Warnings and precautions to bring to the user’s attentionMDR Annex I 23.2(m)
Single use (“Do not re-use”)MDR Annex I 23.2(n)

Language: No French found — devices sold in France are labelled in French (MDR Art. 10(11), loi n° 94-665).

Check by eye: The device’s name and what it is for (23.2(a)(b)); the CE marking, with the notified body’s four-digit number where one was involved (Art. 20); ISO 15223-1 symbols (factory, LOT, SN, hourglass, MD, EC REP, STERILE, do not re-use) are pictures — Drict reads only words, so a symbol used alone shows as not found.

Official sources

Questions

What must a label for medical devices sold in France show?

Manufacturer’s name and registered address — MDR Annex I 23.2(c); Lot number (LOT) or serial number (SN) — MDR Annex I 23.2(g); UDI carrier — MDR Annex I 23.2(h), Art. 27; Use-by date, or the date of manufacture when there is none — MDR Annex I 23.2(i)(j); The indication that it is a medical device (“MD”) — MDR Annex I 23.2(q). Items needed only in some cases are listed separately on this page; check the official text before you print.

What language must the label be in for France?

No French found — devices sold in France are labelled in French (MDR Art. 10(11), loi n° 94-665).

Which law sets the label rules for medical devices in France?

The points on this page come from: Regulation (EU) 2017/745 on medical devices (MDR). Each item names its article; the official texts are linked under Official sources.

Does a clean Drict report mean my label is legal in France?

No. Drict finds the particulars the law names by their usual words and links the law; it cannot judge claims, figures, symbols or letter sizes. Use it as a first pass before a regulatory review, never instead of it.